<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">vdgtu</journal-id><journal-title-group><journal-title xml:lang="ru">Вестник Дагестанского государственного технического университета. Технические науки</journal-title><trans-title-group xml:lang="en"><trans-title>Herald of Dagestan State Technical University. Technical Sciences</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2073-6185</issn><issn pub-type="epub">2542-095X</issn><publisher><publisher-name>Daghestan State Technical University</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.21822/2073-6185-2024-51-3-35-41</article-id><article-id custom-type="elpub" pub-id-type="custom">vdgtu-1552</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ЭНЕРГЕТИКА И ЭЛЕКТРОТЕХНИКА</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>ENERGY AND ELECTRICAL ENGINEERING</subject></subj-group></article-categories><title-group><article-title>Методика охлаждения серверных помещений</article-title><trans-title-group xml:lang="en"><trans-title>Method of cooling server rooms</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Страшко</surname><given-names>Е. И.</given-names></name><name name-style="western" xml:lang="en"><surname>Strashko</surname><given-names>E. I.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Страшко Егор Игоревич, студент, кафедра технологического оборудования и систем жизнеобеспечения</p><p>350072, г. Краснодар, ул. Московская, д. 2 </p></bio><bio xml:lang="en"><p>Egor I. Strashko, Student, Department of Technological Equipment and Life Support Systems </p><p>2 Moskovskaya St., Krasnodar 350072 </p></bio><email xlink:type="simple">tukann.tukann@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Шорсткий</surname><given-names>И. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Shortsky</surname><given-names>I. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Шорсткий Иван Александрович, кандидат технических наук, доцент кафедры технологического оборудования и систем жизнеобеспечения</p><p>350072, г. Краснодар, ул. Московская, д. 2 </p></bio><bio xml:lang="en"><p>Ivan A. Shortsky, Cand. Sci. (Eng), Assoc. Prof., Departmentof Technological Equipment and Life Support Systems </p><p>2 Moskovskaya St., Krasnodar 350072 </p></bio><email xlink:type="simple">thegector@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Жлобо</surname><given-names>Р. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Zhlobo</surname><given-names>R. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Жлобо Руслан Андреевич, старший преподаватель кафедры технологического оборудования и систем жизнеобеспечения</p><p>350072, г. Краснодар, ул. Московская, д. 2 </p></bio><bio xml:lang="en"><p>Ruslan A. Zhlobo, Senior Lecturer, Department of Technological Equipment and Life Support Systems </p><p>2 Moskovskaya St., Krasnodar 350072 </p></bio><email xlink:type="simple">rzhlobo@bk.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Кубанский государственный технологический университет</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Kuban State Technological University</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2024</year></pub-date><pub-date pub-type="epub"><day>01</day><month>10</month><year>2024</year></pub-date><volume>51</volume><issue>3</issue><fpage>35</fpage><lpage>41</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Страшко Е.И., Шорсткий И.А., Жлобо Р.А., 2024</copyright-statement><copyright-year>2024</copyright-year><copyright-holder xml:lang="ru">Страшко Е.И., Шорсткий И.А., Жлобо Р.А.</copyright-holder><copyright-holder xml:lang="en">Strashko E.I., Shortsky I.A., Zhlobo R.A.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://vestnik.dgtu.ru/jour/article/view/1552">https://vestnik.dgtu.ru/jour/article/view/1552</self-uri><abstract><p>Цель. В современном мире, где количество данных растет с каждым днем, важность надежных и эффективных центров обработки данных (ЦОД) становится все более очевидной. Одним из ключевых аспектов поддержания работоспособности и надежности ЦОД является обеспечение адекватного охлаждения серверных помещений. Данная научная работа посвящена изучению и анализу различных методик охлаждения, используемых в серверных помещениях. Метод. Исследование основано на методах термодинамического анализа для оптимизации систем охлаждения с целью повышения их эффективности и снижения энергопотребления. Результат. В работе рассматриваются как традиционные системы охлаждения, так и современные инновационные решения, позволяющие повысить эффективность охлаждения при одновременном снижении энергопотребления. Авторы проводят сравнение различных методов охлаждения, оценивают их преимущества и недостатки, а также анализируют потенциальные экономические и экологические выгоды от внедрения передовых технологий в практику управления серверными помещениями. Вывод. Выбор оптимального метода охлаждения должен учитывать специфику серверного оборудования, тепловые нагрузки, размер помещения и другие факторы. Важно также уделить внимание обслуживанию и выбору оптимальной системы охлаждения в соответствии с потребностями и характеристиками серверного оборудования.</p></abstract><trans-abstract xml:lang="en"><p>Objective. In today's world, where the amount of data is growing every day, the importance of reliable and efficient data centers (DPCs) is becoming increasingly clear. One of the key aspects of maintaining data center availability and reliability is ensuring adequate cooling of server rooms. This scientific work is devoted to the study and analysis of various cooling techniques used in server rooms. Method. The study is based on thermodynamic analysis methods to optimize cooling systems to improve their efficiency and reduce energy consumption. Result. The work examines both traditional cooling systems and modern innovative solutions that improve cooling efficiency while reducing energy consumption. The authors compare different cooling methods, evaluate their advantages and disadvantages, and analyze the potential economic and environmental benefits of introducing advanced technologies into server room management practices. Conclusion. The choice of the optimal cooling method should take into account the specifics of the server equipment, thermal loads, room size and other factors. It is also important to pay attention to maintenance and selection of the optimal cooling system in accordance with the needs and characteristics of the server equipment.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>центры обработки данных</kwd><kwd>серверные помещения</kwd><kwd>системы охлаждения</kwd><kwd>энергоэффективность</kwd><kwd>инновационные решения</kwd><kwd>экономическая эффективность</kwd><kwd>экологическая безопасность</kwd></kwd-group><kwd-group xml:lang="en"><kwd>data processing centers</kwd><kwd>server rooms</kwd><kwd>cooling systems</kwd><kwd>energy efficiency</kwd><kwd>innovative solutions</kwd><kwd>economic efficiency</kwd><kwd>environmental safety</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Полухин А.Т., Радачинская А.А. Анализ и разработка интеллектуального алгоритма охлаждения серверного помещения и пост использование паразитного тепла//Достижения вузовской науки. 2016. № 23. С. 131-135.</mixed-citation><mixed-citation xml:lang="en">Polukhin A.T., Radachinskaya A.A. Analysis and development of an intelligent cooling algorithm for server rooms and post-use of waste heat. Achievements of university science. 2016; 23: 131-135. (In Russ)</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Сонич В.Ф., Бурков А.И. К вопросу о применении прецизионных кондиционеров в Пермском крае//Вестник Пермского национального исследовательского политехнического университета. Строительство и архитектура. 2013. № 2. С. 107-115.</mixed-citation><mixed-citation xml:lang="en">Sonich V.F., Burkov A.I. On the application of precision air conditioners in the Perm region. Bulletin of the Perm National Research Polytechnic University. Construction and Architecture. 2013;2:107-115. (In Russ)</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Глушков С.С. Энергосбережение и охлаждение в "ЦОД"//Научно-исследовательский центр "Technical Innovations". 2023. № 19. С. 192-196.</mixed-citation><mixed-citation xml:lang="en">Glushkov S.S. Energy conservation and cooling in "DPC". Scientific Research Center "Technical Innovations". 2023;19:192-196. ( In Russ)</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Комаров Е.Г., Лозовецкий В.В., Лебедев В.В., Черкина В.М.Моделирование системы автономной теплофикации при трансформации тепловой энергии, образующейся в серверных станциях//Лесной вестник. Forestry Bulletin. 2021. Т. 25. № 1. С. 130-139.</mixed-citation><mixed-citation xml:lang="en">Komarov E.G., Lozovetsky V.V., Lebedev V.V., Cherkina V.M. Modeling of the autonomous heating system during the transformation of thermal energy generated in server stations. Forestry Bulletin. 2021;(25): 1:130-139. ( In Russ)</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Полев И.Г., Сергеев А.И. Комбинированная система по мониторингу и регулированию температуры в серверном помещении//Интеграционные процессы в науке в современных условиях. Сб. статей Международной научно-практической конференции. Ответ. редактор: Сукиасян А.А. 2016. С. 38-42.</mixed-citation><mixed-citation xml:lang="en">Polev I.G., Sergeyev A.I. Combined system for monitoring and regulating the temperature in a server room. Integration processes in science in modern conditions. Collection of articles of the International scientific-practical conference. Responsible editor: A. A. Sukiasyan. 2016; 38-42. (In Russ)</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Жилкина Н.В. Планирование инфраструктуры ЦОД//Вестник связи 2006. № 11. С. 94-103.</mixed-citation><mixed-citation xml:lang="en">Zhilkina N.V. Planning of data center infrastructure. Communication Bulletin 2006; 11: 94-103. ( In Russ)</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Арбатский А.А., Глазов В.С. Обеспечение охлаждения в дата-центре сверхвысокой загрузки//Вестник Московского энергетического института. 2018. № 4. С. 36-43.</mixed-citation><mixed-citation xml:lang="en">Arbatsky A.A., Glazov V.S. Ensuring cooling in a high-load data center. Bulletin of the Moscow Power Engineering Institute. 2018;4:36-43. ( In Russ)</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Ронжин П.Л., Мартынюк А.В. Системы кондиционирования с внутренним дублированием для датацентров// Cети и системы связи 2008. № 14. С. 12-15.</mixed-citation><mixed-citation xml:lang="en">Ronzhin P.L., Martynyuk A.V. Air conditioning systems with internal redundancy for data centers. Networks and Communication Systems 2008; 14: 12-15. ( In Russ)</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Ахкозов В.В. Определение параметров объекта в системе приточной вентиляции с помощью математического моделирования//Инновационные перспективы Донбасса. Материалы межд.научно-практической конференции. Донецкий национальный технический университет. 2015. С. 62-66.</mixed-citation><mixed-citation xml:lang="en">Akkozov V.V. Determination of object parameters in the supply ventilation system using mathematical modeling. Innovative perspectives of Donbass. Materials of the International scientific-practical conference. Donetsk National Technical University. 2015; 62-66.( In Russ)</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Еремкин А.И., Фильчакина И.Н. Воздухораспределитель для равномерной раздачи приточного воздуха через оппозитные щели в системах вытесняющей вентиляции//Региональная архитектура и строительство. 2011. № 2 С. 128-134.</mixed-citation><mixed-citation xml:lang="en">Eremkin A.I., Filchakina I.N. Air distributor for uniform distribution of supply air through opposing slots in displacement ventilation systems. Regional Architecture and Construction. 2011;2:128-134. ( In Russ)</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Палеев Д.Ю., Киселев Ю.Е., Козлов В.И. Приточная вентиляция - проблемы и перспективы//Безопасность жизнедеятельности предприятий в промышленно развитых регионах. Материалы Х Международной научно-практической конференции. 2013. С. 166-169.</mixed-citation><mixed-citation xml:lang="en">Paleev D.Y., Kiselev Y.E., Kozlov V.I. Supply ventilation - problems and prospects. In the collection: Occupational safety of enterprises in industrially developed regions. Materials of the X International scientific-practical conference. 2013;166-169.( In Russ)</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Ахмедов Д.Ш., Елубаев С.А., Абдолдина Ф.Н. Применение системы жидкостного охлаждения в персональной гибридной вычислительной системе на базе графических процессоров// Научный сервис в сети Интернет: многообразие суперкомпьютерных миров. Труды Межд.суперкомпьютерной конференции. РАН. Суперкомпьютерный консорциум университетов России. 2014. С. 280-288.</mixed-citation><mixed-citation xml:lang="en">Akhmedov D.S., Elubaev S.A., Abdoldina F.N. Application of liquid cooling system in a personal hybrid computing system based on graphics processors. Scientific service on the Internet: diversity of supercomputer worlds. Proceedings of the International Supercomputer Conference. RAS. 2014; 280-288. ( In Russ)</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Кондурцова Т.М. Двухфазная система жидкостного охлаждения серверов// Перспективные направления развития отечественных информационных технологий. Материалы III межрегиональной научнопрактической конференции. Научный редактор Б.В. Соколов. 2017. С. 147-149.</mixed-citation><mixed-citation xml:lang="en">Kondurtsova T.M. Two-phase liquid cooling system for servers. In the collection: Promising directions for the development of domestic information technologies. Materials of the III interregional scientific and practical conference. Scientific editor B.V. Sokolov. 2017; 147-149. ( In Russ)</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Гаврилова О.А., Андреев А.И., Семенов А.Е., Чанчиков В.А.Экономическая эффективность использования полупроводникового охлаждения компьютерной техники//Вестник Астраханского государственного технического университета. Серия: Экономика. 2023. № 4. С. 58-66.</mixed-citation><mixed-citation xml:lang="en">Gavrilova O.A., Andreev A.I., Semenov A.E., Chanchikov V.A. Economic efficiency of using semiconductor cooling for computer equipment. Bulletin of the Astrakhan State Technical University. Series: Economics. 2023; 4: 58-66. ( In Russ)</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Ворончихин С.Г., Помыткин В.А., Земцов М.А., Флаксман А.Л. Определение влияния турбулизатора в теплообменнике на термическое сопротивление системы водяного охлаждения микрочипов//Научное обозрение. 2015. № 21. С. 173-177.</mixed-citation><mixed-citation xml:lang="en">Voronchikhin S.G., Pomytkin V.A., Zemtsov M.A., Flaxman A.L. Determining the influence of a turbulator in a heat exchanger on the thermal resistance of a water cooling system for microchips. Scientific Review. 2015; 2: 173-177. ( In Russ)</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Ивашко Е.Е.Разработка математических моделей и информационных систем для повышения энергетической эффективности вычислительных кластеров и центров обработки данных с использованием прогнозирования нагрузки//НИР: грант № 13-07-98801. РФФИ. 2013.</mixed-citation><mixed-citation xml:lang="en">Ivashko E.E. Development of mathematical models and information systems to increase the energy efficiency of computing clusters and data processing centers using load forecasting. Research project: grant No. 13-07-98801. RFBR. 2013. ( In Russ)</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Юлдашев А.Р., Морева Ю.А.Применение вычислительных систем с иммерсионным охлаждением в качестве дополнительного источника тепла для отопления помещений различного назначения //Актуальные проблемы современной науки, техники и образования. 2023. Т. 14. № 2. С. 23-26.</mixed-citation><mixed-citation xml:lang="en">Yuldashev A.R., Moreva Y.A. Application of computing systems with immersion cooling as an additional source of heat for heating premises of various purposes. Current Issues in Modern Science, Technology and Education. 2023;14( 2):23-26. ( In Russ)</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Пискун Г.А., Алексеев В.Ф., Беликов А.Н., Рыбаков Д.Г. Моделирование отведения тепловой энергии от процессоров при помощи кулеров воздушного охлаждения//Доклады Белорусского государственного университета информатики и радиоэлектроники. 2023. Т. 21. № 4. С. 54-62.</mixed-citation><mixed-citation xml:lang="en">Piskun G.A., Alexeev V.F., Belikov A.N., Rybakov D.G. Modeling of heat dissipation from processors using air cooling coolers. Reports of the Belarusian State University of Informatics and Radioelectronics. 2023; 21(4):54-62.</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Свиридов А.Н., Демкин В.И. Анализ методов повышения энергоэффективности центров обработки данных//Современные наукоемкие технологии. 2022. № 2 С. 110-115.</mixed-citation><mixed-citation xml:lang="en">Sviridov A.N., Demkin V.I. Analysis of methods for increasing energy efficiency of data processing centers. Modern hightech technologies. 2022; 2:110-115. (In Russ)</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Шарун К.В., Баранова А.В. Разработка блока контроля температуры системы охлаждения серверов модульного типа//Перспективные технологии в средствах передачи информации. Материалы 14-ой международной научно-технической конференции. Владимир, 2021. С. 253-255.</mixed-citation><mixed-citation xml:lang="en">Sharun K.V., Baranova A.V. Development of a temperature control unit for a modular type server cooling system. Prospective technologies in information transmission means. Materials of the 14th International Scientific and Technical Conference. Vladimir, 2021; 253-255. (In Russ)</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
